Exhibits
Exhibit 50
Description:
RF ANALYSIS

AN EXISTING TOWER AND BUILDING ARE PROPOSED.

THE PROPOSED ANTENNA SYSTEM CONSISTS OF TWO EACH JAMPRO JUHD PANELS, TWO HORIZONTALLY POLARIZED AND TWO VERTICALLY POLARIZED, WITH A RADIATION CENTER 61 METERS ABOVE GROUND. FORMULA 10 OF OET BULLETIN NO. 65, EDITION 97-01, PAGE 22, HAS BEEN USED TO CALCULATE POWER DENSITY. A VALUE F OF 0.15 HAS BEEN USED TO CALCULATE THE POWER DENSITY 2 METERS ABOVE GROUND. THE MAXIMUM POWER DENSITY IS 6.48 UW/CM SQUARED FOR AN ERP OF 15,000 WATTS H. POL. AND 15,000 WATTS V. POL. THIS VALUE IS 1.5 % OF THE ALLOWABLE 431.3 UW/CM SQUARED POWER DENSITY FOR UNCONTROLLED ENVIRONMENTS FOR TV CHANNEL 43 AND, THUS, IS BELIEVED TO COMPLY FULLY WITH OET-65 GUIDELINES.

THE TOWER BASE WILL BE FENCED TO PREVENT UNAUTHORIZED ACCESS AND WARNING SIGNS PLACED AS REQUIRED BY OET-65 GUIDELINES.

THE APPLICANT WILL REDUCE, OR CEASE, TRANSMISSION AS REQUIRED TO MEET FCC OET-65 GUIDELINES FOR WORKER EXPOSURE.


Attachment 50